Quality Inspection for Cooling Incubator - DRK-GHP Electrothermal Constant Temperature Incubator(New) – Drick

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

High quality Very first,and Shopper Supreme is our guideline to offer the most beneficial company to our clients.Nowadays, we're hoping our best to be certainly one of the top exporters in our area to satisfy consumers additional will need for Pesticide Residue Testing Cost, Temperature Incubator, Automatic Pesticide Residue Tester Meter, We always regard the technology and customers as the uppermost. We always work hard to create great values for our customers and offer our customers better products & services.
Quality Inspection for Cooling Incubator - DRK-GHP Electrothermal Constant Temperature Incubator(New) – Drick Detail:

1.Compound door structural design,the built-in super wide-angle glass inner door is convenient for users to observe the test samples without dead angles.

2.Patented dual chamber temperature control system, which greatly improves the uniformity of the temperature in the box

3. Standard large-screen LCD display, multiple sets of data on one screen, menu-style operation interface, easy to understand and easy to operate.

4.It adopts mirror-finished stainless steel inner tank, four corners and semi-circular arc design, easy to clean, and the spacing of the partitions in the box is adjustable.

7.Adopt JAKEL pipe flow circulation fan, unique design of air duct, create good air circulation and convection, and ensure temperature uniformity.

8.PID control mode, small fluctuations in temperature control accuracy, with timing function, the maximum time setting is 99 hours and 59 minutes.

1.Intelligent Program Controller-30-segment(此处不确定) programming function to meet the needs of complex experiments.

2.Embedded printer-convenient for customers to print data.

3.Independent limit temperature alarm system-if the limit temperature is exceeded, the heating source is forced to stop, escorting your laboratory safety.

4.RS485 interface and special software-connect to a computer, export experimental data.

Tern

9052N

9082N

9162N

9272N

Voltage

AC220V  50HZ

Temperature range

RT+5~65℃

Temperature fluctuation

±0.5℃

Temperature uniformity

±0.5℃

Temperature resolution

0.1℃

Input Power

250W

350W

550W

700W

Liner size

W×D×H(mm)

345×355×410

400×400×500

500×500×650

600×600×750

Dimensions

W×D×H(mm)

480×545×665

535×590×755

635×690×905

735×790×1005

Volume

50L

80L

160L

270L

Shelf distance(mm)

46

46

63

74

Standard partition/layer number

2/8

2/10

2/10

2/10

Timing range

1~9999min

Note: The performance parameter test is under no-load conditions, no strong magnetism, no vibration: ambient temperature 30℃, ambient humidity 50%RH.


Product detail pictures:

Quality Inspection for Cooling Incubator - DRK-GHP Electrothermal Constant Temperature Incubator(New) – Drick detail pictures


Related Product Guide:

Innovation, quality and reliability are the core values of our company. These principles today more than ever form the basis of our success as an internationally active mid-size company for Quality Inspection for Cooling Incubator - DRK-GHP Electrothermal Constant Temperature Incubator(New) – Drick , The product will supply to all over the world, such as: Uruguay, Bulgaria, California, In order to make more people know our products and to enlarge our market, we have devoted a lot of attention to technical innovations and improvement, as well as replacement of equipment. Last but not the least, we also pay more attention to training our managerial personnel, technicians and workers in planned way.
  • The factory workers have a good team spirit, so we received high quality products fast, in addition, the price is also appropriate, this is a very good and reliable Chinese manufacturers.
    5 Stars By Victor from Jamaica - 2018.12.05 13:53
    Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
    5 Stars By Julie from Burundi - 2017.11.11 11:41
    Write your message here and send it to us