New Delivery for Forced Air Incubator - DRK-LRH Biochemical Incubator Series – Drick

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

"Control the standard by the details, show the toughness by quality". Our firm has strived to establish a highly efficient and stable workers workforce and explored an effective high-quality management system for Electric Incubator, Pesticide Residue Testing Canada, Pesticide Residues Water Analysis, We welcome new and previous clients from all walks of lifetime to get in touch with us for future small business interactions and mutual success!
New Delivery for Forced Air Incubator - DRK-LRH Biochemical Incubator Series – Drick Detail:

★1.Observation window, which is convenient for users to observe the test sample without dead angle.

★2.Patented double greenhouse temperature control system, which greatly improves the uniformity of the temperature inside the cabinet

★3.The cooling capacity intelligent control system, which automatically adjusts the compressor cooling power, and has the cooling capacity return function to help the compressor cool down quickly and extend the service life of the compressor.

4.Standard large-screen LCD display, multiple sets of data displayed on one screen, menu-style operation interface, easy to understand and easy to operate.

5.Mirror stainless steel liner, semi-circular arc design at four corners, easy to clean, adjustable partitions in the box.

6.Adopting international brand compressors and self-developed compressor cooling system, which can effectively extend the life of the compressor.

7.Adopt JAKEL pipe flow circulation fan, uniquely designed air duct, create good air circulation and convection, and ensure temperature uniformity.

8.PID control mode, low temperature control accuracy fluctuation, with timing function, the maximum time setting is 99 hours and 59 minutes.

9.Committed to the world environmental health initiative, using 134a fluorine-free refrigerant, high efficiency, energy saving and environmental protection.

1. BOD special socket-built-in power socket, convenient for the built-in instrument to power on.

2. Intelligent program controller-30-segment programming function to meet the needs of complex experiments.

3. Embedded printer-convenient for customers to print data.

4. Independent limit temperature alarm system-if the limit temperature is exceeded, the heating source is forced to stop, escorting your laboratory safety.

5. RS485 interface and special software-connect to a computer to export experimental data.

6. Test hole 25mm/50mm-can be used to test the actual temperature in the working room.

Project

70F

150F

250F

500F

1000F

1700F

Voltage

AC220V  50HZ

AC380V 50HZ

Temperature control range

0~65℃

10~50℃

Constant temperature fluctuation

high temperature±0.3℃  Low temperature±0.5℃

Temperature uniformity

±0.5℃(No load)

±2.0℃(No load)

Temperature resolution

0.1℃

compressor

Import Danfoss compressor from Denmark

Relay

Schneider

Studio material

304stainless steel

refrigerating system

Fluorine-free environmental protection

input power

400W

700W

1150W

2050W

4100W

4500W

Liner size

W×D×H(mm)

450×320×500

480×390×780

580×500×850

700×700×1020

1050×590×1610

1600×600×1800

Dimensions

W×D×H(mm)

575×545×1070

605×625×1350

705×725×1525

825×995×1780

1410×890×1950

2310×890×2100

Nominal volume

70L

150L

250L

500L

1000L

1700L

Carrying bracket (standard

2pcs

3pcs

4pcs

16pcs

Timing range

1~9999min

Note: The performance parameter test under no-load conditions, no strong magnetism, no vibration: ambient temperature 20 ℃, ambient humidity 50% RH.

1000L and other customized non-standard incubators can be customized according to user needs (customized product cycle is 30 to 40 working days after order confirmation).

When the input power is ≥2000W, it is equipped with 16A plug, and other products are equipped with 10A plug

The performance parameter test under no-load conditions, no strong magnetism, no vibration: ambient temperature 20 ℃, ambient humidity 50% RH.
1000L and other customized non-standard incubators can be customized according to user needs (customized product cycle is 30 to 40 working days after order confirmation).
When the input power is ≥2000W, it is equipped with 16A plug, and other products are equipped with 10A plug


Product detail pictures:

New Delivery for Forced Air Incubator - DRK-LRH Biochemical Incubator Series – Drick detail pictures


Related Product Guide:

"Quality 1st, Honesty as base, Sincere company and mutual profit" is our idea, in an effort to create consistently and pursue the excellence for New Delivery for Forced Air Incubator - DRK-LRH Biochemical Incubator Series – Drick , The product will supply to all over the world, such as: Montreal, kazan, Norwegian, If you have any requests, pls email Us with your detailed demands, we will give you the most wholesale Competitive Price with the Super Quality and the Unbeatable First-class Service ! We can give you the most competitive prices and high quality, because we are much more PROFESSIONAL! So please do not hesitate to contact us.
  • It is really lucky to meet such a good supplier, this is our most satisfied cooperation, I think we will work again!
    5 Stars By Vanessa from San Diego - 2018.07.26 16:51
    The company can keep up with the changes in this industry market, product updates fast and the price is cheap, this is our second cooperation, it's good.
    5 Stars By Jane from South Africa - 2017.11.01 17:04
    Write your message here and send it to us