Manufacturer for Rain Spray Test Chamber - DRK-LRH Biochemical incubator series – Drick

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our company sticks into the basic principle of "Quality is definitely the life of the business, and status may be the soul of it" for Small Lab Incubator, Muffle Oven, Incubator In Hindi, Seeing believes! We sincerely welcome the new customers abroad to set up business relationships and also expect to consolidate the relationships with the long-established customers.
Manufacturer for Rain Spray Test Chamber - DRK-LRH Biochemical incubator series – Drick Detail:

★1.Observation window, which is convenient for users to observe the test sample without dead angle.

★2.Patented double greenhouse temperature control system, which greatly improves the uniformity of the temperature inside the cabinet

★3.The cooling capacity intelligent control system, which automatically adjusts the compressor cooling power, and has the cooling capacity return function to help the compressor cool down quickly and extend the service life of the compressor.

4.Standard large-screen LCD display, multiple sets of data displayed on one screen, menu-style operation interface, easy to understand and easy to operate.

5.Mirror stainless steel liner, semi-circular arc design at four corners, easy to clean, adjustable partitions in the box.

6.Adopting international brand compressors and self-developed compressor cooling system, which can effectively extend the life of the compressor.

7.Adopt JAKEL pipe flow circulation fan, uniquely designed air duct, create good air circulation and convection, and ensure temperature uniformity.

8.PID control mode, low temperature control accuracy fluctuation, with timing function, the maximum time setting is 99 hours and 59 minutes.

9.Committed to the world environmental health initiative, using 134a fluorine-free refrigerant, high efficiency, energy saving and environmental protection.

1. BOD special socket-built-in power socket, convenient for the built-in instrument to power on.

2. Intelligent program controller-30-segment programming function to meet the needs of complex experiments.

3. Embedded printer-convenient for customers to print data.

4. Independent limit temperature alarm system-if the limit temperature is exceeded, the heating source is forced to stop, escorting your laboratory safety.

5. RS485 interface and special software-connect to a computer to export experimental data.

6. Test hole 25mm/50mm-can be used to test the actual temperature in the working room.

Project

70F

150F

250F

500F

1000F

1700F

Voltage

AC220V  50HZ

AC380V 50HZ

Temperature control range

0~65℃

10~50℃

Constant temperature fluctuation

high temperature±0.3℃  Low temperature±0.5℃

Temperature uniformity

±0.5℃(No load)

±2.0℃(No load)

Temperature resolution

0.1℃

compressor

Import Danfoss compressor from Denmark

Relay

Schneider

Studio material

304stainless steel

refrigerating system

Fluorine-free environmental protection

input power

400W

700W

1150W

2050W

4100W

4500W

Liner size

W×D×H(mm)

450×320×500

480×390×780

580×500×850

700×700×1020

1050×590×1610

1600×600×1800

Dimensions

W×D×H(mm)

575×545×1070

605×625×1350

705×725×1525

825×995×1780

1410×890×1950

2310×890×2100

Nominal volume

70L

150L

250L

500L

1000L

1700L

Carrying bracket (standard

2pcs

3pcs

4pcs

16pcs

Timing range

1~9999min

Note: The performance parameter test under no-load conditions, no strong magnetism, no vibration: ambient temperature 20 ℃, ambient humidity 50% RH.

1000L and other customized non-standard incubators can be customized according to user needs (customized product cycle is 30 to 40 working days after order confirmation).

When the input power is ≥2000W, it is equipped with 16A plug, and other products are equipped with 10A plug

The performance parameter test under no-load conditions, no strong magnetism, no vibration: ambient temperature 20 ℃, ambient humidity 50% RH.
1000L and other customized non-standard incubators can be customized according to user needs (customized product cycle is 30 to 40 working days after order confirmation).
When the input power is ≥2000W, it is equipped with 16A plug, and other products are equipped with 10A plug


Product detail pictures:


Related Product Guide:

Our company insists all along the quality policy of "product good quality is base of enterprise survival; buyer fulfillment will be the staring point and ending of an company; persistent improvement is eternal pursuit of staff" and also the consistent purpose of "reputation very first, shopper first" for Manufacturer for Rain Spray Test Chamber - DRK-LRH Biochemical incubator series – Drick , The product will supply to all over the world, such as: French, San Francisco, Belgium, We've a skilled sales team, they have mastered the best technology and manufacturing processes, have years of experience in foreign trade sales, with customers able to communicate seamlessly and accurately understand the real needs of customers, providing customers with personalized service and unique merchandise.
The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
5 Stars By lucia from Jamaica - 2017.04.18 16:45
Timely delivery, strict implementation of the contract provisions of the goods, encountered special circumstances, but also actively cooperate, a trustworthy company!
5 Stars By James Brown from Croatia - 2018.02.08 16:45
Write your message here and send it to us