DRK-G300 Laser Particle Size Analyzer (Wet and Dry Dual-Use)
DRK-G300 Laser Particle Size Analyzer (Wet and Dry Dual-Use) is an all-round particle size analysis instrument. This instrument adopts a split design, with the sampler and the main unit separated. It supports wet and dry detection dispersion methods, enabling more convenient mode expansion and conversion. Thanks to its plug-in pipeline design, switching the detection method can be achieved by simply matching the corresponding sampler and detection window. Additionally, micro-volume, large-capacity, or corrosion-resistant sampling systems can be selected as accessories.
DRK-G300 laser particle size analyzer is based on the full-range Mie scattering theory. Its design fully complies with ISO international technical standards. Structurally, it uses a pure helium-neon gas light source and a large-angle, non-uniform, crossed, fan-shaped, super-large detector array. This design takes full account of the detection angle and sensitivity, ensuring a wide testing range as well as the accuracy and repeatability of the test results.
The ultrasonic dispersion system of the DRK-G300 laser particle size analyzer can fully disperse the sample to be tested. The high-power ultrasonic generator (100W) is equipped with a dry-running protection design. The ultrasonic time can be adjusted automatically and continuously. Users can set it according to the difficulty of sample dispersion. With good shielding, ultrasonic dispersion and sample testing can be carried out simultaneously. Even particles with strong agglomeration can be fully dispersed, enabling the acquisition of real particle size distribution data.
The sample dispersion cell is made of stainless steel. It has a unique circular design, facilitating liquid circulation and drainage. The micro-arc design prevents dirt accumulation, making it easy to clean, and it is also equipped with a liquid level protection device.
The wet dispersion method has automated functions such as automatic water inlet, automatic testing, automatic optical path status determination, automatic bubble elimination, and automatic cleaning. Liquids like distilled water, pure water, and alcohol can be used as the dispersion medium.
Select an appropriate circulation stirring speed according to the characteristics of the sample to be tested to prevent particle sedimentation in the circulation pipeline. The circulation pump speed can be adjusted automatically and continuously, with a digital display for settings. When the ultrasonic function is turned on during the testing process, it can avoid testing errors caused by bubbles generated due to excessive circulation speed and prevent particle agglomeration during the circulation process.
The sample is evenly conveyed into the high-pressure airflow through the automatic dry powder sampler. Driven by the high-pressure airflow, it is continuously and rapidly sprayed into the disperser. By the time it reaches the outlet of the disperser, the sample has been fully dispersed. After passing through the laser beam, the sample enters the collector or vacuum cleaner, and the particle size distribution information is immediately displayed on the computer.
Specification Model | DRK – 300W (Wet), DRK – 300D (Dry), DRK – G300 (Wet and Dry Dual-Use) |
Testing Range | Wet: 0.01 – 3000μm Dry: 0.1 – 3000μm |
Repeatability Error | < 1% (National Standard Reference Material D50) |
Measurement Principle | Mie Scattering Principle |
Accuracy Error | < 1% (National Standard Reference Material D50) |
Measurement Method | Wet: Stirring and Ultrasonic Dual-Stage Dispersion Dry: Duck-Bill-Shaped Nozzle, Oscillation and Venturi Dual-Stage Dispersion |
Optical Path System | High-Transmittance Coated Single Lens, High-Precision Three-Dimensional Automatic Centering, Optical Path Automatic Determination and Warning Function |
Laser Light Source | Pure Helium-Neon Gas Laser |
Sample Cell | 400ml Micro-Arc Bottom, with Physical Liquid-Level Meter, Designed to Prevent Particle Aggregation and Deposition |
Detector | Sensitive Large-Area Detection Units, Distributed in Front, Rear, and Side Double-Row Three-Dimensions |
Operation Method | Both wet and dry methods support one-key full-automatic and manual operation |
Circulation Rotation Speed | Up to 5000 revolutions, continuously adjustable |
Ultrasonic Generator | 100W, adjustable from 0 – 9 minutes and 50 seconds, with dry-running protection design |
Interface Method | Dual Communication of Network Port and USB |
Instrument Structure | Split-Type, Metal Body, Quick-Insert Pipelines |
It is suitable for particle size analysis and testing in various fields, including powder coatings, building materials (cement), metallurgy and chemical engineering, coal and minerals, pharmaceuticals and pesticides, health products, ceramic abrasives, catalysts, precious metals, etc. Examples include heavy calcium carbonate, light calcium carbonate, talcum powder, kaolin, graphite, wollastonite, brucite, barite, mica powder, bentonite, diatomite, clay, silica, garnet, zirconium silicate, zirconia, magnesium oxide, zinc oxide, river sediment, lithium-battery materials, catalysts, phosphor powders, cement, abrasives, pharmaceuticals, pesticides, food, coatings, dyes, ceramic raw materials, chemical materials, nanomaterials, paper-making fillers and coatings, and various emulsions.
Based on the design principle of the all-round laser particle size analyzer, it can be used to detect not only solid powder particles but also mixed solutions such as suspensions and emulsions.
(1) The PADMAS (Particle Diameter Measure & Analysis System) is a powerful and feature-rich software. It can process test data through functions such as averaging, statistics, comparison, and trend analysis. It has multiple formats, including differential distribution, cumulative distribution, standard classification, volume distribution, area distribution, number distribution, R-R distribution, custom classification, and classification by mesh size. 
(Data Trend)
(2) High Visibility: The testing software has a user-friendly interface. The testing process is clearly visible, with instant refresh. Users can observe the operating status of the instrument and the fluctuation of test data at any time, and analyze the authenticity and reliability of the measured data.
(3) Objective and Real: The analysis software performs automatic calculations.
(4) Easy to Operate: Standardized, quantitative, and simple operations can be mastered in a short time.
For customers in the pharmaceutical industry, the software complies with the GMP regulations of the Pharmacopoeia. It has functions such as audit trail, electronic signature, permission setting, and data immutability. It can also provide 3Q templates to assist in 3Q certification.
The test report includes a particle size distribution curve, a detailed particle size data table, and a custom simple table. It contains characteristic parameters such as D3, D10, D50, D90, D97, D(1,0), D(3,2), D(4,3), span, peak particle size, and specific surface area. There are also multiple custom parameters that can be input as needed. The weight-based specific surface area and volume-based specific surface area can be interchanged. The particle size distribution graph and particle size data chart can be saved as pictures. It also supports PDF, WORD, and EXCEL report templates. It supports printing test reports in Chinese and English. The header and footer can be modified as required, and there is a print preview function.
Comprehensive technical training, detailed operation manuals, and online software help enable operators to accurately operate the equipment, solve problems, and troubleshoot malfunctions.
Based on the physical and chemical properties of samples, such as density, anisotropy, brittleness, magnetism, toxicity, fluidity, agglomeration, solubility, and physical and chemical reactions, we have developed a scientific, systematic, and complete dispersion testing plan, which is provided to users along with the instrument. We not only sell the instrument but also offer dispersion testing solutions.
Note: Due to technological advancements, the information may be changed without prior notice. The product shall be subject to the actual product delivered later.