Good quality Incubator Humidity Pads - DRK-LRH Biochemical incubator series – Drick

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our company since its inception, always regards product quality as enterprise life, continuously improve production technology, improve product quality and continuously strengthen enterprise total quality management, in strict accordance with the national standard ISO 9001:2000 for Shaking Incubator, Aging Test Chamber, Handheld Pesticide Residue Meter, We sincerely do our greatest to supply the very best support for every one of the purchasers and businessmen.
Good quality Incubator Humidity Pads - DRK-LRH Biochemical incubator series – Drick Detail:

★1.Observation window, which is convenient for users to observe the test sample without dead angle.

★2.Patented double greenhouse temperature control system, which greatly improves the uniformity of the temperature inside the cabinet

★3.The cooling capacity intelligent control system, which automatically adjusts the compressor cooling power, and has the cooling capacity return function to help the compressor cool down quickly and extend the service life of the compressor.

4.Standard large-screen LCD display, multiple sets of data displayed on one screen, menu-style operation interface, easy to understand and easy to operate.

5.Mirror stainless steel liner, semi-circular arc design at four corners, easy to clean, adjustable partitions in the box.

6.Adopting international brand compressors and self-developed compressor cooling system, which can effectively extend the life of the compressor.

7.Adopt JAKEL pipe flow circulation fan, uniquely designed air duct, create good air circulation and convection, and ensure temperature uniformity.

8.PID control mode, low temperature control accuracy fluctuation, with timing function, the maximum time setting is 99 hours and 59 minutes.

9.Committed to the world environmental health initiative, using 134a fluorine-free refrigerant, high efficiency, energy saving and environmental protection.

1. BOD special socket-built-in power socket, convenient for the built-in instrument to power on.

2. Intelligent program controller-30-segment programming function to meet the needs of complex experiments.

3. Embedded printer-convenient for customers to print data.

4. Independent limit temperature alarm system-if the limit temperature is exceeded, the heating source is forced to stop, escorting your laboratory safety.

5. RS485 interface and special software-connect to a computer to export experimental data.

6. Test hole 25mm/50mm-can be used to test the actual temperature in the working room.

Project

70F

150F

250F

500F

1000F

1700F

Voltage

AC220V  50HZ

AC380V 50HZ

Temperature control range

0~65℃

10~50℃

Constant temperature fluctuation

high temperature±0.3℃  Low temperature±0.5℃

Temperature uniformity

±0.5℃(No load)

±2.0℃(No load)

Temperature resolution

0.1℃

compressor

Import Danfoss compressor from Denmark

Relay

Schneider

Studio material

304stainless steel

refrigerating system

Fluorine-free environmental protection

input power

400W

700W

1150W

2050W

4100W

4500W

Liner size

W×D×H(mm)

450×320×500

480×390×780

580×500×850

700×700×1020

1050×590×1610

1600×600×1800

Dimensions

W×D×H(mm)

575×545×1070

605×625×1350

705×725×1525

825×995×1780

1410×890×1950

2310×890×2100

Nominal volume

70L

150L

250L

500L

1000L

1700L

Carrying bracket (standard

2pcs

3pcs

4pcs

16pcs

Timing range

1~9999min

Note: The performance parameter test under no-load conditions, no strong magnetism, no vibration: ambient temperature 20 ℃, ambient humidity 50% RH.

1000L and other customized non-standard incubators can be customized according to user needs (customized product cycle is 30 to 40 working days after order confirmation).

When the input power is ≥2000W, it is equipped with 16A plug, and other products are equipped with 10A plug

The performance parameter test under no-load conditions, no strong magnetism, no vibration: ambient temperature 20 ℃, ambient humidity 50% RH.
1000L and other customized non-standard incubators can be customized according to user needs (customized product cycle is 30 to 40 working days after order confirmation).
When the input power is ≥2000W, it is equipped with 16A plug, and other products are equipped with 10A plug


Product detail pictures:

Good quality Incubator Humidity Pads - DRK-LRH Biochemical incubator series – Drick detail pictures


Related Product Guide:

Gaining purchaser gratification is our firm's intention eternally. We will make wonderful endeavours to build new and top-quality merchandise, satisfy your exclusive needs and provide you with pre-sale, on-sale and after-sale products and services for Good quality Incubator Humidity Pads - DRK-LRH Biochemical incubator series – Drick , The product will supply to all over the world, such as: Mauritius, Suriname, Guatemala, Our solutions are widely recognized and trusted by users and can meet continuously changing of economic and social needs. We welcome new and old customers from all walks of life to contact us for future business relationships and mutual success!
  • We are old friends, the company's product quality has been always very good and this time the price is also very cheap.
    5 Stars By Tony from Honduras - 2018.06.18 19:26
    Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
    5 Stars By Renata from Mumbai - 2017.02.14 13:19
    Write your message here and send it to us