Excellent quality Thermolyne 1500 Furnace - DRK-FX-D302B Cooling-Water-Free Kjeltec Azotometer – Drick

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our pursuit and corporation aim should be to "Always satisfy our consumer requirements". We carry on to build and style and design remarkable quality items for both our outdated and new clients and reach a win-win prospect for our clients at the same time as us for Shaking Incubator, Xenon Arc Test Chamber, Muffle Furnace Size, We are keeping durable small business relationships with additional than 200 wholesalers in the USA, the UK, Germany and Canada. For anyone who is intrigued in any of our products, make sure you experience free to speak to us.
Excellent quality Thermolyne 1500 Furnace - DRK-FX-D302B Cooling-Water-Free Kjeltec Azotometer – Drick Detail:

Based on the principle of Kjeldahl method, the Azotometer is applied to the determination of protein or total nitrogen content,in feed,  food, seeds, fertilizer, soil sample and so on.

Measuring range ≥ 0.1mg N;
Percent recovery  ≥99.5%;
Repeatability  ≤0.5%;
The speed of Detection  distillation time is 3-10 minutes / samples;
The amount of sample  solid samplele≤ 6g; liquid sample  ≤ 20ml;
The peak power  2.5KW;
Distillation power adjustable range  1000W ~1500W;
Refrigeration power  345W
Dilution water  0 ~ 200Ml;
Alkali  0~200mL;
Boric acid  0 ~ 200mL;
Distillation time  0 ~ 30 minutes;
Power supply  AC 220V + 10% 50Hz;
Instrument weight  35kg;
Outline dimension  390*450*740;
External reagent bottles  1 boric acid bottle, 1 alkali bottle, 1 distilled water bottle.

1.The first cooling-water-free condensation technology of the world: based on the second generation DDP cooling-water-free condensation technology, the Azotometer can effectively condense without using cooling water, never worry about the high temperature or low press of cooling water. The revolutionary technology has three advantages. First of all, it condenses at 1℃, the water vapor and ammonia is liquefied Immediately, and the ammonia can be absorbed without loss,So the result is reliable, accurate and reproducible. Secondly, it can save a lot of water in the experiments, in line with the current trend of water saving. While traditional Azotometer using fluid water to cool down, consuming about 10L of water per minute, if it works 8 hours a day, 1200 tons of water will be wasted every year. Thirdly, it is unnecessary to configure faucet or cycle chiller Individually, so that it can be placed anywhere in the lab.

2.The experimental data can be reproduced accurately: firstly, the steam monitoring technology ensures that the effective distillation time and the setting distillation time can be consistent completely. Secondly, the stability of the steam is controlled precisely by microcomputer. Thirdly, comparing with normal Azotometers which use pneumatic pipetting technique, our devices add a regulator system innovatively to guarantee the consistency of each dosing, so the data is more accurate.

3.Intelligent automation: using a colorful touch-screen make the operation easy and convenient. In addition, the process of adding boric acid, adding alkali, distilling and rinsing is all automatic.

4.The material of the Azotometer is of great quality and anti-corrosion: We use CE certification pressure pumps, valves and Saint-Gobain brands imported pipes.

5.Applied flexibly: the distillation power is adjustable; the Instrument is suitable for experimental research.

2

Weigh the sample

3

Dissolve

4

Digestion

5

Digestion solution

6

Put into the Azotometer

7

Titration

8

  Result

We have many famous experts and professors who lead the industry development , and they have devoted for the instrument development and application of technology for at least 50 years . As the expert in the industrial applications, we are the most authoritative scientific instruments and laboratory applications, and we are also the project designer and provider who understand the need of inspectors.


Product detail pictures:


Related Product Guide:

Our corporation puts emphasis about the administration, the introduction of talented staff, plus the construction of team building, attempting hard to improve the quality and liability consciousness of team members. Our organization successfully attained IS9001 Certification and European CE Certification of Excellent quality Thermolyne 1500 Furnace - DRK-FX-D302B Cooling-Water-Free Kjeltec Azotometer – Drick , The product will supply to all over the world, such as: kazakhstan, Israel, Nigeria, Our company upholds the spirit of "innovation, harmony, team work and sharing, trails, pragmatic progress". Give us a chance and we will prove our capability. With your kind help, we believe that we can create a bright future with you together.
This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
5 Stars By Gustave from Somalia - 2018.02.21 12:14
Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
5 Stars By Elsa from Borussia Dortmund - 2018.12.14 15:26
Write your message here and send it to us