DRK310 Single-chamber Gas Permeability Tester (differential pressure method)

Short Description:


  • FOB Price: US $0.5 - 9,999 / set
  • Min.Order Quantity: 1 set/sets
  • Supply Ability: 10000 set/sets per Month
  • Product Detail

    Product Tags

    Gas permeability test. Suitable for O2, CO2, N2 and other non-toxic gas permeability testing of plastic films, composite films, high barrier materials, sheets, metal foils, rubber and other materials.

    Differential pressure method of gas permeability tester:
    Place the pre-set sample between the high-pressure chamber and the low-pressure chamber, compress and seal, and then vacuum the high and low-pressure chambers at the same time; after vacuuming for a certain period of time and the vacuum degree drops to the required value, close the low-pressure chamber and move to the high-pressure chamber. Fill the chamber with test gas and adjust the pressure in the high-pressure chamber to maintain a constant pressure difference on both sides of the sample; the gas penetrates from the high-pressure side of the sample to the low-pressure side under the action of the pressure difference; accurately measure the pressure change in the low-pressure chamber and calculate The gas permeability performance parameters of the sample.

    The gas permeability tester complies with the standard:
    YBB 00082003, GB/T 1038, ASTM D1434, ISO 2556, ISO 15105-1, JIS K7126-A.

    Technical Characteristics
    Imported high-precision vacuum sensor, pressure sensor, high test accuracy;
    The thermostatic bath has two-way temperature control, parallel connection, high reliability;
    Precise valve and piping parts, thorough sealing, high-speed vacuum, thorough desorption, reducing test errors;
    The sample is designed to prevent side leakage to reduce the leakage of the sample installation;
    Precise pressure control to maintain the pressure difference between the high and low pressure chambers in a wide range;
    Patented baseline technology removes system background leakage and reduces test errors;
    Intelligent Auto: Power-on self-test, to avoid failure to continue the test; one-key start, fully automatic execution of the test.
    Data recording: Graphical, full process and full element recording, data will not be lost after power failure.
    Data security: optional “GMP computerized system” software module, with user management, authority management, data audit trail and other functions.
    Working environment: indoor. There is no need for a constant temperature and humidity environment (to reduce the cost of use), and the test data is not affected by the environmental temperature and humidity.

    Name Parameter Name Parameter
    Test Error 0.01 cm3/m2•day•0.1MPa Correction Method Standard Film
    Vacuum Error 0.1Pa Vacuum Range 1333.33 Pa
    Vacuum <10 Pa Vacuum Efficiency Less than 27Pa in 20 minutes
    Temperature Range 15℃~50℃ Temperature Control Error ±0.1℃
    Sample Thickness ≤3mm Test Area 50cm2 (round)
    Test Gas O2, N2, CO2, non-toxic gas Test Pressure 0.1~0.2 MPa
    Gas Interface 1/8″ Air Pressure 0.1~0.8 MPa
    Power Type AC220V 50Hz Power <1500 W
    Model Distinction Model
    DRK310
    Measuring Range 0.1-50,000
    Number of Samples 1
    Number of Vacuum Sensors 1
    Test mode Single Chamber Independent
    Host size (L×B×H) 585×640×380mm
    Host Weight 50Kg

     

    Standard Configuration
    The test host, vacuum pump, test software, vacuum bellows, gas cylinder pressure relief valve and pipe fittings, sealing grease, 21.5-inch DELL display, and computer host are built into the test host.
    Optional accessories: container test fixture, humidity control unit.
    Self-prepared parts: test gas and cylinder


  • Previous:
  • Next:

  • Write your message here and send it to us