DRK251 Thermal Index Test Chamber is suitable for the heat resistance test, electronic parts, and plasticized products of electrical insulation materials.
Features
1. The thermal aging test chamber is made of CNC machine tools, and the shape is beautiful, novel and non-reverse force handle, easy to operate.
2, the cabinet is made of imported high-grade stainless steel (SUS304) mirror plate or 304b argon arc welding, the case is sprayed with A3 steel plate, which increases the appearance and cleanliness.
3, using a thermally controlled intelligent program microcomputer controller, timing function, precise temperature control is accurate.
4. Large-scale observation window attached to the lanterns in the box, and utilizes tempered glass, at any time, clear observations.
5, the hot air circulation system consists of a fan and special airway that can be continuously operated at a high temperature, and the working indoor temperature is uniform.
6. The aging box device is equipped with a low speed turntable.
7. The thermal aging test chamber insulation uses ultrafine glass fiber insulation cotton to avoid unnecessary energy loss.
8. The time and number of ventilation can be set.
Applications
The thermal aging test chamber is suitable for the heat resistance test, electronic parts, and plasticized products of electrical insulation materials.
Technical Standard
Instrument complies with relevant standards and regulations such as JB7444-1994 GB / T3512-2014
Product parameters
Performance Index | Model (cm) | LP / QLH-100 | LP / QLH-225 | LP / QLH-500 | LP / QLH-800 | LP / QLH-010 |
Studio size | 45 * 45 * 50 | 50 * 60 * 75 | 70 * 80 * 90 | 80 * 100 * 100 | 100 * 100 * 100 | |
Dimensions | 125 * 125 * 178 | 135 * 138 * 205 | 148 * 165 * 225 | 158 * 185 * 238 | 187 * 185 * 238 | |
Power | 3.0 (kW) | 4.5 (kW) | 5.5 (kW) | 6.5 (kW) | 6.5 (kW) | |
Temperature range | RT + 10 ° C ~ 200 ° C, 300 ° C | |||||
Evenness | ± 2 ° C | |||||
Constant temperature fluctuation | ± 0.5 ° C | |||||
Ventilation time | 1MIN ~ 99H adjustable | |||||
Convergence | 2 ~ 100 times / h | |||||
Control System | Control system | Imported LED Digital P.I.D + S.S.R. Microcomputer Integrated Controller | ||||
Precision range | Setting accuracy: temperature ± 0.1 ° C, indication accuracy: temperature ± 0.1 ° C, resolution: ± 0.1 ° C | |||||
Timing range | 1 ~ 9999min | |||||
Circulatory system | High temperature resistant low noise motor. Multi-leaf centrifugal wind wheel | |||||
Turntable diameter | Φ250mm | Φ350mm | Φ500mm | φ600mm | φ800mm | |
Safety Protection | Leakage, short circuit, over temperature, motor overheating, overcurrent protection |
Product Configuration
Host one, certificate, manual