DRK250 Constant Temperature &Humidity Chamber
Technical description of the instrument:
It is mainly used to measure the moisture permeability of all kinds of fabrics, including permeable coated fabrics. Structure principle: adopt computer control, creating a constant temperature, and humidity test environment, test environment in the constant temperature, and humidity, moisture vapor transmission cup, placed 6 sample into the glass and the rubber gasket seal, the containing hygroscopic agent or water seal is specified by the wet cup placed in the fabric sample temperature and humidity of the environment, the seal moisture vapor transmission cup according to a certain time (including sample and hygroscopic agent or water) to calculate the moisture transmission quality change.
Testing standard:
GB19082-2009 medical primary protective clothing technical requirements
Guidelines for the selection of YY-T1498-2016 medical protective clothing
GB/T12704.1 determination of moisture permeability of fabrics -- hygroscopic method
Detailed technical specifications and configuration
Technical indicators:
1.Temperature control range: 0℃ ~ 100℃;Resolution;0.1 ℃
2.Humidity control range: 20%RH ~ 98%RH±5%
3.Speed range: 2mm ~ 60mm/min
4.Control precision: temperature ≤0.1℃;Humidity + / - 1% RH or less
5.Cyclic wind speed: 0.02 ~ 0.5m/s, 0.3 ~ 0.5m/s
6.Time control: 1 ~ 9999h
7.Moisture permeable area: 2827 mm 2 (diameter is 60 mm -- national standard)
8.Quantity of permeable cups: 6 gb;
9.Drying box control temperature: room temperature ~ 199℃
10.Test time: 1 ~ 999h
11.Drying box studio size: 400X450X550mm
Instrument configuration:
1. One main machine
Attachment:
Model (DRK250) |
Studio Size(mm) |
Dimensions(mm) |
Temperature Range |
Power |
Remarks Content |
100L |
400×450×550 |
930×930×1600 |
0~100℃ |
220V/2W |
I. The humidity range of all equipment is: 30%~98%R.H (or 20%~98%R.H);II.The delivery time is usually 20 days, and some products can be shortened to 7 days (to be determined in advance).III.All the devices in this quotation are LCD touch screen temperature and humidity controllers, programmable (that is, programmable constant temperature and humidity test boxes). IV.Non-standard equipment requires a single check price
|
-20~100℃ |
220V/3KW |
||||
-40~100℃ |
380V/4KW |
||||
-70~100℃ |
380V/5KW |
||||
150L |
500×500×600 |
1030×990×1750 |
0~100℃ |
220V/3KW |
|
-20~100℃ |
220V/4KW |
||||
-40~100℃ |
380V/5KW |
||||
-70~100℃ |
380V/6KW |
||||
225L |
500×600×750 |
1030×1100×1900 |
0~100℃ |
220V/4KW |
|
-20~100℃ |
380V/5KW |
||||
-40~100℃ |
380V/6KW |
||||
-70~100℃ |
380V/8KW |
||||
408L |
600×800×850 |
1200×1280×2100 |
0~100℃ |
220V/4KW |
|
-20~100℃ |
380V/5KW |
||||
-40~100℃ |
380V/6.5KW |
||||
-70~100℃ |
380V/9KW |
||||
800L |
800×1000×1000 |
1400×1480×2300 |
0~100℃ |
380V/5KW |
|
-20~100℃ |
380V/6.5KW |
||||
-40~100℃ |
380V/8KW |
||||
-70~100℃ |
380V/11KW |
||||
1000L |
1000×1000×1000 |
1600×1480×2300 |
0~100℃ |
380V/6KW |
|
-20~100℃ |
380V/8KW |
||||
-40~100℃ |
380V/11KW |
||||
-70~100℃ |
380V/14KW |