★1.Standard large-screen LCD display, multiple sets of data on one screen,menu-style operation interface, easy to understand and easy to operate.
★2.The fan speed control method is adopted, and the wind speed can beadjusted freely according to different experiments.
3.The self-developed air duct circulation system automatically discharges thewater vapor inside the box, and there is no need to worry about manual adjustment.
4.It adopts a controller with over-temperature deviation protection and a microcomputer PID fuzzy processing controller to quickly reach the preset temperature and run stably.
5.It adopts mirror-finished stainless steel inner tank, four corners and semi-circular arc design, easy to clean, and the spacing of the partitions in the box is adjustable.
6.The sealing design of the new synthetic silicon sealing strip effectively prevents heat loss, and can extend the length of each component on the basis of 30% energy saving Life.
7.Adopt JAKEL pipe flow circulation fan, unique design of air duct, create good air circulation and convection, and ensure temperature uniformity.
8.PID control mode, low temperature control accuracy fluctuation, with timing function, the maximum time setting is 9999 minutes.
1.Embedded printer-convenient for customers to print data.
2.Independent limit temperature alarm system-if the limit temperature is exceeded, the heating source is forced to stop, escorting your laboratory safety.
3.RS485 interface and special software-connect to a computer to export experimental data.
4.Test hole 25mm/50mm-can be used to test the actual temperature in the working room.
5.Intelligent program controller-30-step programming process can be set to meet various complex experiments.
Project |
9070A |
9140A |
9240A |
9420A |
9620A |
9920A |
Power |
AC220V 50HZ |
AC380V 50HZ |
||||
Temperature control range |
RT+10~300℃ |
|||||
Constant temperature fluctuation |
±1℃ |
|||||
Constant temperature fluctuation |
±2.5% |
|||||
Temperature resolution |
0.1℃ |
|||||
Studio material |
304 stainless steel |
|||||
Input power |
1100W |
1550W |
2050W |
3500W |
4000W |
6000W |
Liner size W×D×H(mm) |
400×425×445 |
450×550×550 |
500×600×750 |
600×550×1300 |
800×640×1290 |
1000×600×1600 |
Dimensions W×D×H(mm) |
545×580×800 |
640×710×905 |
680×800×1205 |
780×750×1850 |
980×750×1750 |
1180×800×2150 |
Nominal volume |
80L |
136L |
225L |
420L |
620L |
1000L |
Carrying bracket (standard) |
2pcs |
3pcs |
4pcs |
|||
Timing range |
1~9999min |
Note: The performance parameter test under no-load conditions, no strong magnetism,
no vibration: ambient temperature 20 ℃, ambient humidity 50% RH.
When the input power is ≥2000W, a 16A plug is configured, and the rest of the products are configured with a 10A plug.