★1.Compound door structural design,the built-in super wide-angle glass inner door is convenient for users to observe the test samples without dead angles.
★2.Patented dual chamber temperature control system, which greatly improves the uniformity of the temperature in the box
★3.Cooling capacity intelligent control system automatically adjusts the compressor refrigeration power and has the refrigeration reflux function to help the compressor cool down quickly and extend the service life of the compressor.
4.Standard large-screen LCD display, multiple sets of data on one screen, menu-style operation interface, easy to understand and easy to operate.
5. The standard 25mm test hole is convenient for users to measure data.
6.It adopts mirror-finished stainless steel inner tank, four corners and semi-circular arc design, easy to clean, and the spacing of the partitions in the box is adjustable.
7.With international brand compressors and the self-developed compressor cooling system,it can effectively extend the life of the compressor.
8.Adopt JAKEL pipe flow circulation fan, unique design of air duct, create good air circulation and convection, and ensure temperature uniformity.
9. PID control mode, small fluctuations in temperature control accuracy, with timing function, the maximum time setting is 99 hours and 59 minutes.
10.Committed to the world environmental protection and health initiative, using 134a fluorine-free refrigerant, high efficiency, energy saving and environmental protection.
1.BOD special socket:built-in power socket, convenient for the built-in instrument to power on.
2.Intelligent program controller-30-segment programming function to meet the needs of complex experiments.
3.Embedded printer-convenient for customers to print data.
4.Independent limit temperature alarm system-if the limit temperature is exceeded, the heating source is forced to stop, escorting your laboratory safety.
5.RS485 interface and special software-connect to a computer, export experimental data.
Term |
70FN |
150FN |
250FN |
500FN |
Voltage |
AC220V 50HZ |
|||
TEMP Range |
0~65℃ |
|||
TEMP Fluctuation |
±0.3℃ ±0.5℃ |
|||
TEMP Uniformity |
±0.5℃ |
|||
TMEP Resolution |
0.1℃ |
|||
Compressor |
danfossImported Danfoss compressor from Denmark |
|||
Freezer fan |
Imported German EBM refrigerator fan |
|||
Studio material |
304304 stainless steel |
|||
Cooling System |
Fluorine free |
|||
Input power |
400W |
700W |
1150W |
2050W |
Liner size
W×D×H(mm) |
450×320×500 |
480×390×780 |
580×500×850 |
700×700×1020 |
Dimension W×D×H(mm) |
560×640×1000 |
590×710×1280 |
690×820×1350 |
810×1020×1520 |
Volume |
70L |
150L |
250L |
500L |
Carrying bracket (standard) |
2pcs |
|||
Timing Range |
1~9999min |
Note: The performance parameter test under no-load conditions, no strong magnetism, no vibration: ambient temperature 20 ℃, ambient humidity 50% RH.
Non-standard incubators can be customized according to user needs (customized product time is 30 to 40 working days after order confirmation).
When the input power is ≥2000W, a 16A plug is configured, and the rest of the products are configured with a 10A plug.