★1.Observation window, which is convenient for users to observe the test sample without dead angle.
★2.Patented double greenhouse temperature control system, which greatly improves the uniformity of the temperature inside the cabinet
★3.The cooling capacity intelligent control system, which automatically adjusts the compressor cooling power, and has the cooling capacity return function to help the compressor cool down quickly and extend the service life of the compressor.
4.Standard large-screen LCD display, multiple sets of data displayed on one screen, menu-style operation interface, easy to understand and easy to operate.
5.Mirror stainless steel liner, semi-circular arc design at four corners, easy to clean, adjustable partitions in the box.
6.Adopting international brand compressors and self-developed compressor cooling system, which can effectively extend the life of the compressor.
7.Adopt JAKEL pipe flow circulation fan, uniquely designed air duct, create good air circulation and convection, and ensure temperature uniformity.
8.PID control mode, low temperature control accuracy fluctuation, with timing function, the maximum time setting is 99 hours and 59 minutes.
9.Committed to the world environmental health initiative, using 134a fluorine-free refrigerant, high efficiency, energy saving and environmental protection.
1. BOD special socket-built-in power socket, convenient for the built-in instrument to power on.
2. Intelligent program controller-30-segment programming function to meet the needs of complex experiments.
3. Embedded printer-convenient for customers to print data.
4. Independent limit temperature alarm system-if the limit temperature is exceeded, the heating source is forced to stop, escorting your laboratory safety.
5. RS485 interface and special software-connect to a computer to export experimental data.
6. Test hole 25mm/50mm-can be used to test the actual temperature in the working room.
Project |
70F |
150F |
250F |
500F |
1000F |
1700F |
Voltage |
AC220V 50HZ |
AC380V 50HZ |
||||
Temperature control range |
0~65℃ |
10~50℃ |
||||
Constant temperature fluctuation |
high temperature±0.3℃ Low temperature±0.5℃ |
|||||
Temperature uniformity |
±0.5℃(No load) |
±2.0℃(No load) |
||||
Temperature resolution |
0.1℃ |
|||||
compressor |
Import Danfoss compressor from Denmark |
|||||
Relay |
Schneider |
|||||
Studio material |
304stainless steel |
|||||
refrigerating system |
Fluorine-free environmental protection |
|||||
input power |
400W |
700W |
1150W |
2050W |
4100W |
4500W |
Liner size W×D×H(mm) |
450×320×500 |
480×390×780 |
580×500×850 |
700×700×1020 |
1050×590×1610 |
1600×600×1800 |
Dimensions W×D×H(mm) |
575×545×1070 |
605×625×1350 |
705×725×1525 |
825×995×1780 |
1410×890×1950 |
2310×890×2100 |
Nominal volume |
70L |
150L |
250L |
500L |
1000L |
1700L |
Carrying bracket (standard |
2pcs |
3pcs |
4pcs |
16pcs |
||
Timing range |
1~9999min |
Note: The performance parameter test under no-load conditions, no strong magnetism, no vibration: ambient temperature 20 ℃, ambient humidity 50% RH.
1000L and other customized non-standard incubators can be customized according to user needs (customized product cycle is 30 to 40 working days after order confirmation).
When the input power is ≥2000W, it is equipped with 16A plug, and other products are equipped with 10A plug
The performance parameter test under no-load conditions, no strong magnetism, no vibration: ambient temperature 20 ℃, ambient humidity 50% RH.
1000L and other customized non-standard incubators can be customized according to user needs (customized product cycle is 30 to 40 working days after order confirmation).
When the input power is ≥2000W, it is equipped with 16A plug, and other products are equipped with 10A plug